LAUNDRY APPLICATION
Home Laundry Ozone Engineering Platform
Inline ozone-water engineering for a dedicated home washer connection, designed around actual fill flow and household operating demand.
INLINE OZONE WATERPOINT-OF-USE ENGINEERINGEXISTING WASHER
ENGINEERING SIMULATION
Validate the Home operating point
Essential operating inputs
Enter the measured washer operating point. BES design concentration, WDS mass transfer, washer count and concurrency are fixed for this Basic model.
BES DESIGN STANDARDHome Laundry: 0.30 mg/L
Incoming water must comply with the selected WDS inlet-water specification. Pretreatment or engineering review is required when feed water is outside specification.
Calculated Home operating point
WDS2000X is within the rated hydraulic range and provides sufficient ozone capacity at the measured fill flow.
Hydraulic & Product Sizing
| BES Design Standard | 0.30 mg/L |
|---|---|
| Actual Fill Flow | 8.0 L/min · 480 LPH |
| Required Generator Output | 180.0 mg/h |
| Recommended Product | WDS2000X |
| Selected Product | WDS2000X |
| Estimated Initial Dissolved Ozone | 0.333 mg/L |
| Maximum Supported Flow | 533 LPH · 8.9 L/min |
| Capacity Margin | 11% |
| Ozone Capacity Status | Adequate |
| Hydraulic Range Status | Within Rated Range |
Stage Performance
| Stage | Water | Fill | Initial O₃ | End O₃ | Contact | Stage CT |
|---|---|---|---|---|---|---|
| Main Wash | 20.0 L | 2.50 min | 0.333 mg/L | 0.146 mg/L | 15.0 min | 3.82 mg·min/L |
| Rinse 1 | 20.0 L | 2.50 min | 0.333 mg/L | 0.253 mg/L | 5.0 min | 1.87 mg·min/L |
| Rinse 2 | 20.0 L | 2.50 min | 0.333 mg/L | 0.253 mg/L | 5.0 min | 1.87 mg·min/L |
| Final Rinse | 20.0 L | 2.50 min | 0.333 mg/L | 0.253 mg/L | 5.0 min | 1.87 mg·min/L |
Maintenance
| EOG Runtime per Cycle | 0.167 h |
|---|---|
| EOG Runtime per Day | 0.167 h/day |
| Estimated Monthly EOG Runtime | 5.1 h/month |
| Estimated EOG Life | 1,000 h |
| Estimated Replacement Interval | 197.1 months |
| Ozonated Water per Cycle | 80 L |
| Ozonated Water per Day | 80 L/day |
Fill, Contact and Drain by independent stage
Concentration resets after every Drain. EOG runtime advances only during Fill.