A = Length × Width300 m²Show Calculation
- Engineering inputs
- Length 20 m; width 15 m
- Formula
- A = L × W
- Substitution
- 20 × 15
- Calculation
- 300 m²
- Final result
- 300 m² room area

Select the appropriate BES indoor-air platform and evaluate room coverage, installation architecture, operating profile and engineering suitability.
Choose the engineering architecture.
Generated when Export PDF is selected
Room area
20 × 15 = 300.0 m²
Room volume
300.0 × 4 = 1200.0 m³
Coverage / airflow utilization
400 ÷ 1200 × 100 = 33.3%
3 preliminary airflow zones are indicated by the entered 3 zone plan and 400 m³/h airflow. This is an airflow review only; final HAS Pro sizing requires verified coverage and site distribution data.
Enter the room and operating conditions to calculate coverage where verified, review operating mode and installation architecture, and identify data still required.
A = Length × Width300 m²V = Area × Height1,200 m³N = max(Planned zones, Airflow ÷ 400)3 zonesQinstalled = Quantity × 4001,200 m³/hU = Requested airflow ÷ Installed airflow × 10033.3%Preliminary engineering selection only. This workflow does not confirm sterilization, pathogen kill, ozone exposure safety or final commissioning acceptance.
The BERE blueprint updates product placement, room geometry, airflow direction and engineering annotations from the active platform.
Review the estimated concentration trend against the selected engineering reference and the cumulative exposure trend across the operating window.
Performance curves are presentation estimates based on the selected operating duty and do not modify product sizing, recommendation logic or commissioning acceptance.
Five essential checks summarize the active preliminary selection without repeating the detailed input and recommendation panels.
Generate a print-ready BES report containing the live project inputs, diagram, performance graphs, calculation summary, recommendation and engineering remarks.
A preliminary selection based on the verified platform data and current site inputs.
3 preliminary airflow zones are indicated by the entered 3 zone plan and 400 m³/h airflow. This is an airflow review only; final HAS Pro sizing requires verified coverage and site distribution data.
Detailed engineering interpretation follows the platform’s verified architecture rather than forcing every product into one generic formula.
Use only the verified 100, 200 and 400 m³/h fan levels.
Partitions and return paths define the preliminary zone count.
No area or volume rating is invented for final sizing.
Review airflow and zoning without assigning an unverified room-coverage rating.
Survey partitions, doors, intake paths and discharge paths.
Allocate one clear position to each preliminary airflow zone.
Maintain the documented inlet and side clearances.
Confirm mode, airflow and final quantity with BES Engineering.
This is an engineering screening workflow, not a clinical claim. It does not confirm sterilization, pathogen kill, log reduction or safe ozone exposure.